Fire Doors
KSS metal fire doors are designed to meet the life-safety requirements in various types of buildings and structures. KSS fire doors help compartmentalize the spaces and contain the spread of fire. KSS steel fire doors complement existing passive fire- fighting system
KSS Fire Doors Functions:
KSS fire doors serve five main functions.
- Customize door frames and door sizes
- Serve as a regular door at all times
- Provide ready egress from a fire area during a
- Inhibit spreading of fire
- Protect life and property by reducing smoke
- KSS Fire Door also serve as a temperature rise door as its core integrity range is from 23 to 30 minutes


Fire Door Advantages
- Customize door frames and door sizes being local Manufacturer
- Serve as a regular door at all times as of high strength and quality
- Provide ready egress from a fire area during a fire.
- Inhibit spreading of fire
- Protect life and property by reducing smoke hazards.
- KSS Fire Door also serve as a Temperature Rise Door door as its core integrity range is from 23 to 30 Minutes which allow free movement at unexposed side
KSS Fire Door Selection Guide
At KSS, we are equipped to offer fire doors tested and certified to American and British Standards. The significant requirements of each of these standards are listed below.
- A fire door must have a label attached indicating the fire test rating
- Doors are rated for “/ time of the rating of the surrounding wall.
- Every fire door must have a labeled self-latching (Panic bars] device to engage the strike. Dead bolts may not be used in place of latch bolts
- A fire door must be self-closing
- If a fire door is held open, it must be equipped with a listed / tested, heat responsive or electromagnetic device, fusible link or a smoke detection device which is to be closed in case of fire.
- Only listed / tested fire door hard wares shall be used.
- A fire door with glass opening must be provided with a listed / tested glass, a steel frame and glazing bead along with gaskit and spacer
- Every assembly configuration such as transom panel, louver, vision 0 panel, frame material, thickness of metal, lead construction, core type, door set type (single, double or double egress], etc., Must be covered by the test certificate or global assessment report issued by the authentic testing agency.
- Labeling is not obligatory but recommended.
- According to BS, a fire door can be tested in unlatched condition with a self-closing device.
- A fire door must be self-closing. Only the active door leaf of an access panel (service ducts) or cupboards, can however be installed without a closer but with a dead lock and a “Fire Door, Keep Shut” sign placed clearly on the door face.
- Unless shown to be satisfactory when tested as part of a fire door assembly, the components of any hinge on which the door is hung should be fire rated.
- If a fire door is held open, it must be equipped with a tested, automatic release mechanism actuated by an automatic fire detection and alarm system, fusible link (not if door is fitted in an opening provided as means of escape), or a door-closed delay device
- Two Fire doors may be fitted in the same opening so that the total fire resistance is the sum of their individuals fire resistance.
KSS UL 10 C Steel Stiffened Doors Details
STEEL FIRE DOOR
Specification:
- Type : Single and double
- Door Thickness : 45mm
- Finish : Powder coating / Epoxy Coating
- Astragal : On active leaf of double
Fire Ratings:
ANSI / UL1OC- Up to 12O minutes.